What Is Structural Glazing? Types, Components and How It Works

Structural glazing is a façade glazing method in which glass is bonded to an aluminium frame with high-strength structural silicone, instead of being held by visible pressure plates and caps. The silicone transfers wind load from the glass to the frame, so the outside of the building reads as an almost continuous surface of glass.

It is used on office towers, IT parks, malls, hotels and large homes across India. This guide explains how structural glazing works, the main types, its components and glass, how it differs from a curtain wall, the standards that apply, and what to check before specifying it.

Structural Glazing at a Glance

Question Answer
What is it? A method of fixing glass to a façade frame with structural silicone
What holds the glass against wind? The structural silicone bond between the glass and the aluminium frame
What carries the weight of the glass? In most systems, setting blocks or a mechanical support at the bottom edge
Main configurations Two-sided and four-sided structural glazing
Typical glass Toughened, heat-strengthened or laminated glass, usually in insulating glass units (IGUs)
Where is it used? Commercial façades, shopfronts, atriums, lobbies and premium homes
Key codes and standards NBC 2016 Part 6 Section 8, IS 16231, IS 875 (Part 3), ASTM C1401, ASTM C1184, EN 13022

What Is Structural Glazing?

In conventional, or “captured”, glazing, every edge of the glass sits inside a frame and is held from outside by a pressure plate, cap or glazing bead. In structural glazing, one or more edges are instead bonded to the frame with structural silicone sealant. The technical name is structural silicone glazing (SSG), also called structural sealant glazing.

The silicone is applied to the inner face of the glass, so the aluminium frame sits behind it. From outside, you see glass and narrow silicone joints rather than a metal grid.

What “Structural” Refers To

“Structural” describes the silicone joint, not glass holding up the building. The silicone is a load-bearing part of the façade because it holds the glass against wind. The façade as a whole remains non-load-bearing: it carries its own weight and the wind on it, and passes both to the building frame.

The term is used differently in some markets. In India and North America, structural glazing normally means SSG. Some UK suppliers use it for frameless glass walls, roofs and beams where the glass itself acts as a structural member, which is often called structural glass. When a drawing or quotation says “structural glazing”, confirm which one it means.

How Does Structural Glazing Work?

A structurally glazed façade works by giving every load a defined path from the glass to the building structure.

Load or action What carries it Where it goes
Wind pressure and suction on the glass Structural silicone joint Aluminium frame → mullions → brackets → floor slab
Weight of the glass (dead load) Setting blocks or a mechanical support, in most systems Frame → mullions → brackets → floor slab
Thermal movement between glass and aluminium Flexibility of the silicone joint Absorbed within the joint
Rain and air A separate weatherseal joint and gaskets Sealed at the outer joint; any water that passes is drained

Two dimensions control the structural joint. The bite is the width of silicone in contact with the glass and the frame. The glueline thickness is the depth of silicone between them. Sealant manufacturers’ structural glazing guidelines set a minimum of 6 mm for both, with the bite never smaller than the glueline thickness. The actual bite is calculated for each project from the design wind load and the short side of the glass panel, using methods such as those in ASTM C1401.

The weatherseal is a separate joint. Structural silicone holds the glass; weatherseal silicone keeps water and air out. They are designed and specified separately, even when both are silicone.

Types of Structural Glazing

Most lists of structural glazing “types” mix three separate choices: how each glass edge is supported, how the façade is assembled, and what glass is used. Keeping them apart makes specifications clearer.

Classification What it describes Options
Edge support and fixing method How each glass panel is held Two-sided SSG, four-sided SSG, point-fixed (spider) glazing, glass fin or cable-supported systems
Façade assembly method How the façade is built and installed Stick, unitised, semi-unitised
Glass make-up What the infill panel is Monolithic, laminated, insulating glass unit (double or triple glazed)

A choice from each row can be combined with the others. For example, a unitised façade can use four-sided SSG with double-glazed units.

Two-Sided Structural Glazing

Two opposite edges of each panel are bonded with structural silicone, and the other two are held mechanically by a cap or pressure plate. The façade shows lines in one direction only: vertical lines if the vertical edges are capped, horizontal lines if the horizontal edges are capped.

Two-sided systems suit designs that want a vertical or horizontal emphasis, or projects where the specification asks for mechanical restraint on some edges. Sika, a structural sealant manufacturer, describes the bonded vertical edges with mechanically fixed top and bottom edges as combining transparency with safety.

Four-Sided Structural Glazing

All four edges are bonded, and no aluminium is visible from outside apart from the joints between panels. This is the flush, all-glass look usually associated with structural glazing.

Because the silicone carries all wind load, four-sided SSG depends most on adhesion quality. ASTM C1401 advises that four-sided SSG should not be glazed on a construction site except for breakage replacement or maintenance, so panels are normally bonded in a factory and then installed.

European guidance (EAD 090010-00-0404, which replaced ETAG 002) groups systems by how the glass weight is carried. In Types I and II, the weight is supported mechanically. In Types III and IV, the silicone carries all loads, including the weight of the glass. Whether additional retaining devices are needed in case of bond failure depends on national regulations.

Point-Fixed (Spider) Glazing

Point-fixed glazing holds glass at drilled holes or corners using stainless steel fittings, often called spiders, connected to a steel, cable or glass-fin structure. It is usually listed alongside structural glazing because it achieves a frameless look, but its main load path is mechanical through the fittings, not a continuous silicone bond. The joints between panels are usually weather-sealed with silicone. The same fittings are used in frameless glass canopies.

Glass Fin and Cable-Supported Systems

In tall lobbies and showroom fronts, vertical glass fins set at right angles to the façade can replace aluminium mullions as the members that resist wind. Cable or rod structures do the same job with tensioned stainless steel. The glass may be bonded or point-fixed to these supports, and every such system needs project-specific structural design.

Stick, Unitised and Semi-Unitised: Assembly Methods, Not Glazing Types

Stick, unitised and semi-unitised describe how a façade is built, not how the glass is held. In a stick system, the frame is assembled on site. In a unitised system, complete panels are made in a factory and lifted into place. In a semi-unitised system, the frame is erected on site and factory-glazed sub-frames are fixed to it. Structural glazing can be used with all three.

The assembly method decides where bonding happens. In unitised and semi-unitised systems, glass is bonded to a frame or sub-frame in the factory, which suits the clean, controlled conditions SSG needs. For a full comparison of the three methods, see our guide to curtain wall systems.

Structural Glazing vs Curtain Wall vs Conventional Glazing

A curtain wall is the whole non-load-bearing façade system; structural glazing is one way of fixing the glass within it. So the real comparison is between a structurally glazed curtain wall and a conventional, capped curtain wall.

Feature Conventional (capped) curtain wall Structurally glazed curtain wall
How the glass is held Pressure plates and caps clamp the glass edges from outside Structural silicone bonds the glass to the frame from inside, on two or four sides
Appearance from outside Visible aluminium grid Flush glass with narrow joints (four-sided) or lines in one direction (two-sided)
Where the glass is fixed On site in stick systems; in the factory in unitised systems Usually bonded in a factory; essential for four-sided SSG
Exterior aluminium Caps and pressure plates on every joint Little or none on bonded edges
Replacing a broken pane Remove the caps, replace the glass, refit the caps Cut out the silicone, clean and prepare the frame, re-bond, and restrain the glass until the silicone cures
Quality control focus Gasket fit and pressure plate fastening Adhesion, bite, glueline thickness, cure and material compatibility
IGU edge seal Polysulphide or polyurethane secondary seals are used in some systems, where the edge seal is covered Silicone secondary seal required, because it carries load and may be exposed to sunlight

Both are non-load-bearing. Neither is stronger by default; performance depends on the design, test results and workmanship of the specific system.

Main Components of a Structural Glazing System

A structural glazing system is an assembly of parts that must be designed and tested together, because the silicone has to stay compatible with everything it touches.

Component Function
Glass panel or insulating glass unit (IGU) The infill. In an IGU, the outer pane is held through the unit’s silicone secondary seal.
Structural silicone sealant Bonds the glass to the frame and transfers wind load
Weatherseal silicone and backer rod Seals the joint between panels against water and air
Spacer tape (glazing tape) Sets the glueline thickness and holds the glass while the silicone cures
Setting blocks Support the weight of the glass at the bottom edge and prevent glass-to-metal contact
Aluminium carrier frame or sub-frame The surface the glass is bonded to; its finish must be one the sealant has been tested on
Mullions and transoms Vertical and horizontal members that carry loads to the anchors
Brackets and anchors Fix the system to the floor slab and allow for movement and site tolerances
Retaining devices or toggles Mechanical restraints used in some systems as a backup to the bond
Drainage paths Let any water that passes the outer seal escape
Shadow box (spandrel zone) An opaque, usually insulated zone behind the glass at slab edges and columns
Fire and smoke seal at the slab edge Closes the gap between the façade and the floor slab

Openable Vents in a Structurally Glazed Façade

Structural glazing does not have to mean fixed glass. Top-hung and parallel-opening vents can be structurally glazed so that, from outside, they match the fixed panels. Vent sizes, hardware and the way the glass weight is supported follow the system supplier’s tested details.

Glass Used in Structural Glazing

The glass for structural glazing is chosen from wind load, panel size, building height, safety needs and thermal targets. There is no single correct thickness; it comes from the façade engineer’s calculations for the project.

Glass type Role in structural glazing What to check
Toughened (tempered) glass Higher strength; breaks into small fragments Heat soak testing to EN 14179-1 to reduce the risk of spontaneous breakage from nickel sulphide inclusions
Heat-strengthened glass Stronger than ordinary annealed glass Not a safety glass on its own, so it is usually laminated
Laminated glass The interlayer holds fragments in place after breakage Used where the glass must stay in place after it breaks
Insulating glass unit (DGU or TGU) Improves thermal and acoustic performance Silicone secondary seal sized to carry the outer pane; units suitable for structural use under EN 13022
Coated glass (reflective, solar control, low-E) Controls solar heat gain and glare Some coatings must be removed at the bonded edge (edge deletion); adhesion tested on production samples

Sealant manufacturers require adhesion of structural silicone to be tested on project samples for every glass except clear float glass. In India, glass selection is guided by IS 16231 (Use of Glass in Buildings — Code of Practice) and NBC 2016 Part 6 Section 8.

Where Is Structural Glazing Used?

Structural glazing is used wherever large, uninterrupted glass is part of how a building should look and work.

  • Office towers, IT parks and corporate campuses, where the glass façade forms the building’s identity
  • Malls, showrooms and shopfronts, where flush glass keeps attention on the display
  • Hotels, airports, hospitals and institutional buildings, especially lobbies and atriums
  • Premium homes and villas, for double-height living areas, staircases and garden-facing walls

In homes, structural glazing suits fixed glass areas. Openable areas can use structurally glazed vents or window and door systems such as aluminium windows and doors.

In Indian projects, three site factors need early attention: wind load, which increases with height and depends on the wind zone and terrain under IS 875 (Part 3); heat gain through large areas of glass; and dust, which affects how often the façade must be cleaned.

Advantages and Limitations of Structural Glazing

Structural glazing gives a flush glass façade, but it asks more of design, testing and workmanship than a capped system.

Advantages Limitations
Flush, almost frameless glass appearance Depends heavily on design, adhesion testing and quality control
Little exposed aluminium on bonded edges Replacing a broken pane takes longer and needs specialists
Silicone joints absorb thermal movement between glass and frame The silicone must be compatible with every material it touches
Factory bonding in unitised systems allows controlled quality Four-sided panels should be bonded in a factory, which adds logistics
Works with laminated, insulating and coated glass, once tested Factory bonding, adhesion testing and specialist labour add to the cost

Design and Installation Considerations

Every structurally glazed façade needs project-specific design by a qualified façade engineer. The points below are what owners, architects and contractors should confirm with the engineer and system supplier; they are not installation instructions.

  • Wind load: design pressures come from IS 875 (Part 3) for the site’s wind zone, terrain and building height. The structural bite is sized from these pressures and the panel’s short side.
  • Allowable stress: structural silicone design to ASTM C1401 uses an allowable tensile stress of no more than 138 kPa (20 psi), well below the sealant’s ultimate strength.
  • Movement: the joint must absorb thermal movement, and the façade must accommodate movement between floors from wind and earthquakes. Seismic design in India follows IS 1893.
  • Compatibility and adhesion: gaskets, spacer tape, setting blocks, coatings and frame finishes that touch the structural silicone should be tested for compatibility, and adhesion tested on project materials before production.
  • Factory or site bonding: four-sided SSG should be bonded in a factory, with site glazing kept for breakage replacement or maintenance.
  • Curing: bonded panels should not be moved or loaded until the silicone has cured as specified by the sealant manufacturer.
  • Testing and records: larger projects commonly test a mock-up for air infiltration, water penetration and wind load (for example, ASTM E283, E331 and E330), and keep production records such as adhesion and mixing checks.

Standards and Codes for Structural Glazing in India

Indian codes govern glass selection and wind and seismic loads, and project specifications often reference ASTM and EN standards for structural sealant design and testing.

Code or standard What it covers
NBC 2016, Part 6, Section 8 — Glass and Glazing Selection and use of glass in buildings in India. BIS has circulated a revised draft of this section that adds detailed provisions on glazing systems.
IS 16231 (Parts 1 to 4) — Use of Glass in Buildings, Code of Practice Glass selection, energy and light, fire and loading, and safety related to human impact. All four parts were revised in 2019.
IS 875 (Part 3) Wind loads on buildings and structures
IS 1893 Earthquake-resistant design of structures
IS 3548:1988 Code of practice for glazing in buildings
BIS working draft — Glazing Systems in Buildings, Code of Practice Selection, design, fabrication, installation, testing and maintenance of glazing systems, including curtain walls. Not yet a published standard.
ASTM C1401 Guide for structural sealant glazing design
ASTM C1184 Specification for structural silicone sealants
ASTM C1369 Secondary edge sealants for structurally glazed insulating glass units
EN 13022 (Parts 1 and 2) Structural sealant glazing: glass products and assembly rules
EN 15434 Product standard for structural and UV-resistant sealants
EAD 090010-00-0404 (formerly ETAG 002) European assessment of bonded glazing kits and bonding sealants, including Types I to IV
EN 14179-1 Heat-soaked thermally toughened safety glass

Maintenance and Inspection of Structural Glazing

Structural glazing needs planned inspection, because the silicone joints that hold the glass sit behind it and are not visible from inside the building.

  • Inspect joints for cracks, gaps, discolouration or loss of adhesion, and glass edges for chips.
  • Treat the two joints differently: a weatherseal defect causes leaks, while a structural seal defect is a safety issue that needs a façade specialist.
  • Use cleaning agents approved by the glass and sealant suppliers, as some solvents and abrasive cleaners damage coatings and seals.
  • Follow the inspection intervals in the façade supplier’s maintenance manual.
  • Keep as-built records — sealant type and batch, adhesion test results and glass specifications — to make future replacements easier.

Service life depends on materials, exposure and workmanship. An engineering overview in The Construction Specifier puts the typical service life of SSG façades at 20 to 40 years, usually governed by the life of the glazing materials.

Structural Glazing Façades from Aparna Enterprises

Aparna Enterprises designs, engineers, fabricates and installs aluminium curtain wall systems in stick, unitised and semi-unitised formats as part of its end-to-end façade solutions. Its in-house engineering covers system design, shop drawings, structural and thermal analysis, and project-specific detailing.

Its façade team executes four-sided structural glazing with no external caps, with the system designed to the project’s load requirements. Two-sided structural glazing is also possible, although the team usually prefers a mechanical edge support, such as an edge guard or support leg, for added strength.

Planning a glass façade? Talk to our façade team about system selection, glazing configuration and testing at the design stage.

Frequently Asked Questions on Structural Glazing

Spider glazing holds glass at points with stainless steel fittings. Structural glazing bonds glass edges continuously to a frame with structural silicone. Both look frameless, but loads pass through the fittings in spider glazing and through the silicone joint in structural glazing.

Structural glazing tape is a high-strength, double-sided acrylic foam tape that some systems use to bond glass to the frame instead of structural silicone. It may only be used within the tape manufacturer’s tested limits. It is different from the spacer tape that sets the glueline in silicone-bonded systems.

The cost per square foot depends on the configuration (two-sided or four-sided), the glass (single, laminated or double-glazed, and any coatings), the aluminium system, building height and access, testing requirements and project size. Rates quoted without a full specification are not comparable, so ask every supplier to price the same specification.

Yes. The old silicone is cut out, the frame is cleaned and prepared, and the new glass is bonded and restrained until the silicone cures. It takes longer than replacing glass in a capped system and should be done by the façade supplier or a specialist.

Yes, when the system is designed for the site’s wind load under IS 875 (Part 3) and for building movement, and panels are bonded under factory quality control. Unitised systems are often used on taller buildings; with them, the glass is bonded in the factory before the panels reach site.

Not exactly. Four-sided structural glazing looks frameless from outside, but the glass is bonded to an aluminium frame behind it. “Frameless glazing” is also used for point-fixed and glass-fin systems, and for interior glass partitions.

Start Your Project with the Right Materials